title: "Solving ill-posed inverse problems using iterative deep neural"
description: "Adler and Öktem combine learned image updates with measurement physics to reconstruct images from noisy tomography data in a fixed…"
canonical: "https://research.elamur.ai/free/en/papers/adler-2017-solving-ill-posed-inverse-problems/"
---
Elamur: [Mova](https://md.mova.elamur.ai/free/en/) · [Parse](https://mova.elamur.ai/free/en/parse/) · [Dictionary](https://md.dictionary.elamur.ai/free/en/) · [Translate](https://md.translate.elamur.ai/free/en/) · **Research** · [Gali](https://md.gali.elamur.ai/free/en/) · [MCP](https://mcp.elamur.ai/) · [Locations](https://md.locations.elamur.ai/free/en/) · [Weather](https://md.weather.elamur.ai/free/en/)

[Elamur Research](https://md.research.elamur.ai/free/en/) · [this page in HTML](https://research.elamur.ai/free/en/papers/adler-2017-solving-ill-posed-inverse-problems/)

[Elamur Research](https://md.research.elamur.ai/free/en/) / [papers](https://md.research.elamur.ai/free/en/papers/) / [2017](https://md.research.elamur.ai/free/en/papers/2017/) / Solving ill-posed inverse problems using iterative deep neural networks

# Solving ill-posed inverse problems using iterative deep neural networks

Paper · 2017 · Jonas Adler and Ozan Oktem

**Authors:** [Jonas Adler](https://md.research.elamur.ai/free/en/authors/jonas-adler/) and [Ozan Oktem](https://md.research.elamur.ai/free/en/authors/ozan-oktem/) · **Year:** 2017 · **Venue:** arXiv:1704.04058 · Inverse Problems 2017 · **Licence:** [arXiv — non-exclusive license to distribute](http://arxiv.org/licenses/nonexclusive-distrib/1.0/)

arXiv:1704.04058 · Inverse Problems 2017 · [licence](http://arxiv.org/licenses/nonexclusive-distrib/1.0/)

- [PDF](https://arxiv.org/pdf/1704.04058)
- [DOI 10.1088/1361-6420/aa9581](https://doi.org/10.1088/1361-6420/aa9581)
- [arXiv 1704.04058](https://arxiv.org/abs/1704.04058)

## Summary

A CT scanner measures what happens to X-rays along paths through an object. The image that a reader wants to see, by contrast, describes what is present at each location. Recovering that image from the measurements is an inverse problem. Noise and incomplete sampling make the recovery ill-posed. In practical terms, a small change in the measurements can produce a large change in a reconstruction. Adler and Öktem ask whether a reconstruction algorithm can learn how to handle this instability while using what is already known about the scanner and its measurements.

Their method begins with an image produced by filtered backprojection, a standard way to turn tomographic measurements into an initial reconstruction. At each step, it predicts the data that the current image would produce and calculates a gradient that shows how changes to the image would affect the match to the observed data. It also calculates the gradient of a regularizer, a penalty that expresses a preference about image structure. A convolutional neural network receives these gradients, the current image and a memory of earlier steps. It produces an image correction and updates that memory. Training teaches the network to combine these inputs so that the image at the end of a fixed sequence is close to a known reference.

The authors evaluate the method on two simulations. One uses sparse parallel-beam measurements with additive Gaussian noise and tests reconstruction on a modified Shepp–Logan phantom, a reference image with known structure. The other simulates photon counts from a human head CT slice using a nonlinear description of X-ray transmission and Poisson noise. On the Shepp–Logan test, the learned reconstruction reaches 32.02 dB in peak signal-to-noise ratio, compared with 29.83 dB for total variation reconstruction and 19.75 dB for filtered backprojection. On the selected head slice, the corresponding scores are 43.82 dB, 38.40 dB and 36.12 dB. The learned method reconstructs the 512 × 512 head image in 430 ms on the reported GPU setup. Filtered backprojection takes 130 ms and total variation takes 173,845 ms.

A separate comparison on the Shepp–Logan phantom shows how much the update benefits from its gradient inputs. The reconstruction scores improve when the data discrepancy gradient is supplied and improve again when the regularizer gradient is added. Small features are also easier to see with both inputs. The head comparison raises a separate point about evaluation. The authors see good boundary recovery alongside some possible oversmoothing, and judge the visual improvement to be less striking than the gain in peak signal-to-noise ratio. The tests establish what this learned update can deliver for the simulated acquisitions and reference images studied here. Its behavior across clinical tasks and its convergence as measurement noise vanishes remain open.

## Deep dive: Solving ill-posed inverse problems using iterative deep neural networks

Adler and Öktem combine learned image updates with measurement physics to reconstruct images from noisy tomography data in a fixed number of steps. · about 35 minutes to read

**In this deep dive**

1. [The problem and its context](#dd-the-problem-and-its-context)
2. [The method, step by step](#dd-the-method-step-by-step)
3. [Experiments and results](#dd-experiments-and-results)
4. [What the ablations show](#dd-what-the-ablations-show)
5. [Limitations](#dd-limitations)
6. [What came after](#dd-what-came-after)

### The problem and its context

#### From measurements back to an image

A forward problem starts with the object and asks what an instrument would measure. The inverse problem starts with the instrument's measurements and asks which object produced them. In CT, a location in an image and a location in the measured data describe different things. The former specifies a point in the object. The latter can specify a line through it. A measurement accumulated along a line gives information about many image locations at once, and a location contributes to many measurements. The reconstruction has to reconcile these overlapping contributions with the noise present in the data.

The paper describes this distinction with separate spaces for the signal and the data. In an imaging problem, a signal can be a function defined on an image domain. The data can likewise be a function whose argument identifies a measurement, such as a line specified by the acquisition geometry. This lets the authors describe the mathematical operations on images and measurements before choosing a pixel grid, a collection of detector samples or a particular numerical representation. It also gives a precise home to each of the quantities the algorithm uses. An image estimate belongs to the signal space. A discrepancy between predicted and observed measurements begins in the data space. A gradient used to update the image must ultimately belong to the signal space.

Calling the inverse problem ill-posed has a concrete consequence. A reconstruction that agrees very closely with the measurements can depend strongly on a perturbation that has little to do with the object. If distinct images are difficult to tell apart from the data, an algorithm that concentrates on maximizing their agreement with those data can give importance to the noise. There can also be multiple solutions to the data-fitting problem. The authors therefore treat data fit as evidence that needs to be combined with other information about the image and the measurement process.

#### How classical regularization controls the fit

The paper describes several classical approaches to this problem. An approximate inverse builds a reconstruction map using a smoothing construction available in the signal space. The goal is a usable approximation to inversion. In a different approach, iterative regularization starts from an algorithm that successively improves the data fit. Early termination can regularize the reconstruction when the sequence has a property called semi-convergence. In that situation, early estimates can approach the desired reconstruction while further iterations can become increasingly responsive to noise. The stopping point is then part of the reconstruction procedure.

Variational regularization expresses the tradeoff as an optimization problem. The objective combines a data discrepancy, which measures agreement with the observations, and a regularization functional, which penalizes properties of the image. The noise assumptions enter through the discrepancy. The penalty encodes what the practitioner considers plausible or useful in the recovered signal. A regularization parameter sets the relative influence of the two. For total variation, abbreviated TV, the penalty is based on the magnitude of the spatial gradient. In the paper's imaging context that gives a way to favor images with simple regions while accommodating boundaries.

These approaches place different responsibilities on the user. A variational reconstruction needs a discrepancy, a penalty and a way to choose how strongly to penalize. It also needs a numerical method for the resulting optimization. Sophisticated penalties can make the objective nonsmooth, which calls for algorithms suited to that structure. A more detailed description of the measurements can raise the cost of evaluating the forward operator. Even when the optimization problem has been specified, a practical solver has a finite budget. Its initialization, updates and stopping point help determine the image it actually returns. This distinction between defining an objective and producing a useful image within a computational budget motivates the paper's learned update.

#### Where learning can enter the reconstruction

The paper first considers the direct use of [machine learning](https://md.research.elamur.ai/free/en/concepts/machine-learning/). Training could fit an entire map from measurements to images, using examples of the desired reconstruction. A direct map has a large job. The examples have to convey both the kinds of images the system should recover and how the instrument produces data from those images. The authors note that the geometry of the data can influence the learned mapping and that realistic images and measurement arrays can both be large. The amount and variety of training data needed are therefore central to the practicality of this approach.

Another strategy places a known operation between learned stages. A learned stage can process the data before reconstruction, a known operation can map the result into image space and another learned stage can then improve the image. An important special case starts with a conventional reconstruction and learns only the image-processing stage that follows it. The conventional algorithm handles measurement geometry, and the learned part can draw on methods for denoising images. This arrangement is convenient when the first reconstruction can be computed independently of the learning software. Its capacity to use the original observations depends on what information the initial mapping passes on.

For linear acquisition, the paper also considers using the adjoint of the forward operator as that initial map. In tomography, an adjoint sends contributions from measurements back into image space. Learning what to do with this backprojected information can be viewed as learning to solve the associated normal equations. The authors point out that these equations can themselves be more ill-posed than the original problem. Regularization therefore remains important even when a known operator supplies the connection between data and image.

A further line of prior work learns parameters of a variational objective. The paper describes this as a bilevel problem. One level defines the reconstruction for a given choice of parameters, and the other judges parameter choices using examples. Other work goes further and learns part of the algorithm that solves the problem. The authors discuss precedents that learn an optimizer, an iterative scheme for MRI, a proximal operation for image restoration, or updates for finite-dimensional linear inverse problems. A proximal operation is a step that accounts for a penalty by solving a local minimization problem around a proposed value. These precedents illustrate different choices about which part of an iterative procedure to learn.

Adler and Öktem take up the last direction and broaden it to a formulation in function spaces that can include nonlinear acquisition. They also give the initial reconstruction and the regularizer explicit roles. The recurring operation is an image update that can consult the forward operator through a data discrepancy gradient on each pass. This makes the finite sequence of updates the reconstruction procedure of interest. Training can judge the image that this specific sequence produces, with its allotted number of steps and its chosen initialization.

### The method, step by step

#### What happens when a new measurement arrives

Imagine starting from a filtered backprojection that shows the rough structure of an image, with artifacts from imperfect measurements. The algorithm also starts a set of memory channels at zero. These are image-like arrays carried between updates. They give the next step access to information computed at earlier steps, alongside the image itself.

For each update, the current estimate is sent through the forward operator. The result predicts what the instrument would have observed had that estimate been the true object. A discrepancy measures how the prediction compares with the actual observations under the assumed noise law. Its gradient describes how changing the current image would change the discrepancy. It incorporates the way image changes affect measurements, so the information reaches the update in image coordinates.

In parallel, the algorithm evaluates a regularizer gradient on the same image. The regularizer used in the experiments is built from spatial image gradients. Its derivative supplies a description of local variation that the learned update can use alongside evidence from the measurements. The network receives both gradients, the current image and the old memory. It gives back a signed correction to add to the image and new values for the memory. The procedure then repeats with the changed estimate and the same observed data. The final image is the estimate reached after the prescribed number of updates.

Reconstruction with a learned iterative update The steps in order.

#### The objective that motivates the update

The inverse problem begins with a description of how the observations arise.

```
g = T(fᵗʳᵘᵉ) + δg
```

Here `fᵗʳᵘᵉ` is the unknown true signal in the image or signal space `X`. The forward operator `T` maps `X` to the data space `Y`, and `g` is the observed element of `Y`. The term `δg` is the realized noise contribution. This description can also express a measurement whose noise depends on the clean signal. In the count experiment the authors specify the distribution through the photon counting process, so the statistics of `δg` depend on the predicted measurements.

For an observed `g`, a usual variational reconstruction takes the following form.

```
min over f ∈ X of [L(T(f), g) + λ S(f)]
```

The candidate `f` ranges over `X`, as indicated by `∈`. The function `L` measures discrepancy between predicted data `T(f)` and observed data `g`, using a transformation of the data log-likelihood. The regularizer `S` assigns a real-valued penalty to `f`, and the non-negative parameter `λ` weights it against the discrepancy. The notation `min` expresses the search for a candidate with the smallest combined objective. For classical TV, the paper gives the corresponding penalty as follows.

```
S(f) = ‖∇f‖₁
```

The spatial derivative `∇f` describes variation of the image across locations. The norm `‖ · ‖₁` aggregates the magnitude of that variation, and `S(f)` is the resulting total variation penalty. This is the regularizer behind the TV comparison. The experiments use a different, differentiable regularizer as an input to the learned update.

The authors motivate that update by considering an objective they could evaluate only if they knew the answer.

```
E(f) = d(f, fᵗʳᵘᵉ)
```

The functional `E` measures reconstruction error. The function `d` compares the candidate `f` with the true signal `fᵗʳᵘᵉ`, both in `X`. One choice, also used to motivate the training criterion, is the squared distance in the signal space.

```
E(f) = ‖f − fᵗʳᵘᵉ‖²_X
```

Here `‖ · ‖_X` denotes the norm on `X`. The expression inside it is the image error, and squaring the norm gives the scalar value of `E`. A conventional descent step for this ideal objective would follow the negative error gradient.

```
fⱼ₊₁ = fⱼ − σ ∇E(fⱼ)
```

The index `j` identifies an iteration, `fⱼ` is its image estimate and `fⱼ₊₁` is the next estimate. The symbol `σ` is a step length. The gradient `∇E(fⱼ)` differentiates reconstruction error with respect to the current image. Evaluating it requires the true image, which is available for supervised training examples. The measurements and the assumed image penalty supply gradients that can be evaluated during reconstruction.

Under the differentiability and convexity assumptions used for the motivating argument, a gradient step for the variational objective takes this form.

```
fᵢ = fᵢ₋₁ − σ [∇D_g(fᵢ₋₁) + λ ∇S(fᵢ₋₁)]
```

Here `i` indexes an update and `fᵢ₋₁` and `fᵢ` are the incoming and outgoing images. The notation `D_g` stands for the image-space discrepancy, which evaluates `L` at `T(f)` and the fixed observation `g`. Its gradient is `∇D_g`, and `∇S` is the gradient of the regularizer. The weights `σ` and `λ` are the step length and regularization parameter. The two directions in square brackets are added at the current estimate.

The distinction between a discrepancy in measurement coordinates and its gradient with respect to the image matters when the forward operator is nonlinear. The chain rule gives the conversion.

```
∇D_g(f) = [∂T(f)]* ∇₁L(T(f), g)
```

In this expression `∇₁L` differentiates `L` in its first, predicted-data argument. The derivative `∂T(f)` is the linear operation that describes the first-order effect of an image perturbation at `f` on the predicted data. The star denotes its adjoint, which maps the discrepancy derivative back to image space. The result `∇D_g(f)` can therefore be supplied next to `f` and `∇S(f)`. For a nonlinear `T`, the derivative can depend on `f`, giving the update fresh information about the current image's effect on the measurements.

The paper first proposes a learned operator that receives the current image and these computed directions and approximates the inaccessible gradient of `E`. This is a way to motivate what the update might learn. In the implemented method, the error used for training is evaluated at the reconstruction produced by the full sequence. The individual corrections can therefore serve that final goal by taking different directions at different stages. Classical descent provides the starting analogy for the design. The learned calculation is specified directly by its inputs, its convolutional layers and the way its output is added to the current image.

#### The update and its memory

The final iteration lets the learned operator handle the scale and interaction of the two gradients. It also gives the update persistent state. The simplest reading of the state is a collection of extra images that the network can write at each step and read on the next. Their values are computed alongside the correction. The training objective rewards whatever state is useful for producing the final reconstruction, without giving each memory channel its own target.

```
(sᵢ, Δfᵢ) = Λ_Θ(sᵢ₋₁, fᵢ₋₁, ∇D_g(fᵢ₋₁), ∇S(fᵢ₋₁))
```

The learned update is `Λ_Θ`, with trainable parameters `Θ`. The index `i` labels the current update. The previous state `sᵢ₋₁` and the new state `sᵢ` each contain `M` elements of `X`, where `M` in the update denotes memory size. The current estimate is `fᵢ₋₁`. The remaining inputs are its data discrepancy gradient `∇D_g` for observation `g` and its regularizer gradient `∇S`. The output `Δfᵢ` is an element of `X` with the same shape as the image. The tuple on the left lists the memory and correction the update produces together.

```
fᵢ = fᵢ₋₁ + Δfᵢ
```

The next image `fᵢ` is the previous one `fᵢ₋₁` plus the signed change `Δfᵢ`. As a consequence, the network can refine the current estimate by making spatially varying corrections. The observations continue to influence the procedure through `∇D_g` each time. The fixed starting map and the learned reconstruction map have different roles.

```
f₀ = T†(g)
```

The symbol `T†` denotes an available approximate inverse or pseudo-inverse and `f₀` is the initial image it produces from `g`. In the numerical experiments, this initialization comes from filtered backprojection without an additional smoothing filter. The memory starts at zero. After the specified run, the learned reconstruction is defined by the final image.

```
T†_Θ(g) = f_I
```

Here `T†_Θ` is the complete learned reconstruction map, `I` is the prescribed number of iterations, and `f_I` is the image at the end of that sequence for measurement `g`. The same update parameters appear at each iteration. The inputs change from one step to the next because the image, both calculated gradients and the memory change. Sharing the update in this way gives it a role comparable to a rule applied repeatedly. The paper calls the scheme partially learned because the forward operator, discrepancy, regularizer and initialization are specified separately, while examples determine how the update uses them.

#### What the convolutional layers compute

The update operates on channels. A channel holds one image-space quantity. The initial input channels are the image, the memory channels and the two gradients. In the mathematical formulation the layers map tuples of functions to new tuples of functions. For the experiments these functions are represented on pixel grids. A convolution puts a small set of weights over a neighborhood of pixels and applies those same weights at successive locations. By summing convolutions across the incoming channels, a layer can mix nearby evidence from the current image with nearby values in the gradient and memory arrays.

```
Wⁿₗ(u₁, …, u_cₙ₋₁) = bⁿₗ + ∑ⱼ wⁿⱼ,ₗ ∗ uⱼ
```

The notation `Wⁿₗ` denotes the affine operation that yields output channel `l` in layer `n`. The inputs are `uⱼ`, indexed by `j`, and `cₙ₋₁` is the number of incoming channels. The sum runs over those channels. A kernel `wⁿⱼ,ₗ` connects input channel `j` to output channel `l`, and the star between the kernel and `uⱼ` denotes convolution here. The scalar `bⁿₗ` is a bias added across the output channel. The ellipsis stands for the intermediate channels in the input tuple. The parameter collection `Θ` contains the kernels and biases of the layers.

An affine layer combines inputs linearly and adds a bias. A nonlinear response lets a network built from these layers react differently to different patterns or magnitudes in the inputs. The authors use the rectified linear unit.

```
relu(x) = max(x, 0)
```

The scalar `x` is a channel value at a location, and `max` chooses the larger of `x` and zero. Thus `relu` keeps positive values and maps negative ones to zero. In the implementation, the first two convolutions are followed by this response. The last convolution returns separate outputs for the memory and the image correction. Rectification is applied to the memory output. The image correction is taken directly from the last affine layer, allowing it to either increase or decrease a pixel value.

The update uses `N = 3` layers, with `N` denoting depth. The intermediate channel counts are each 32, and the kernels use 3 × 3 pixel neighborhoods. The number of reconstruction iterations is `I = 10`, and the memory size is `M = 5`. The input width is determined by the memory size plus the image and gradient channels. The output width is determined by the memory size plus the correction. The authors chose the settings by trial and error and kept the update and run length small to restrict the parameter space. Those choices fix both the sequence through which training differentiates and the amount of work the method performs for a new reconstruction.

#### How the CT gradients are calculated

The tomographic experiments share an underlying ray transform. It maps an image to a collection of integrals along the lines defined by the acquisition geometry.

```
P(f)(ℓ) = ∫_ℓ f(x) dx
```

The operator `P` is the ray transform, `f` is the image, and `ℓ` denotes one measurement line. The integral sign `∫` with subscript `ℓ` directs integration along that line. The location `x` ranges along it and `dx` is the line integration element. The result `P(f)(ℓ)` is the accumulated value for that measurement. The collection of all sampled lines defines the data geometry. In the following discrepancy integral, `ℳ` denotes that collection in the continuous notation, distinct from the memory size `M`.

For the ellipse experiment the ray transform itself is the forward operator. The simulated measurements have additive Gaussian noise, and the discrepancy is the squared distance between measured and predicted projection data with a factor of one-half.

```
L(P(f), g) = ½ ‖P(f) − g‖²_Y
```

The quantities `P(f)` and `g` are the predicted and observed projections in `Y`. The norm `‖ · ‖_Y` measures their difference in the data space. The square and factor `½` give the discrepancy used for this setup. The resulting gradient is particularly simple.

```
∇D_g(f) = P*(P(f) − g)
```

The gradient `∇D_g(f)` is taken with respect to the image `f`. The residual `P(f) − g` is a quantity in the data space, and `P*` denotes the adjoint of `P`, which maps that residual to the image space. The fixed linear `P` and its adjoint are sufficient to compute this gradient at each iteration.

For the head experiment, the predicted measurements are photon counts. The line integral determines attenuation through an exponential relation.

```
T(f)(ℓ) = λ exp(−μ P(f)(ℓ))
```

In this formula `T` maps `f` to its predicted mean counts, `ℓ` is the line being measured and `P(f)(ℓ)` is that line's integral through the image. The function `exp` is the exponential. Here `λ` denotes the incident mean number of photons per pixel and has a different meaning from the weight in the earlier variational objective. The coefficient `μ` sets the linear attenuation scale. The simulation takes `λ` to be 10,000 photons per pixel and uses the coefficient for water, approximately 0.2 cm⁻¹. Poisson noise is then applied to the projections. The expected count for an individual measurement is set by `T(f)` at that line, giving the data discrepancy a different form from the one for the ellipse problem.

```
L(T(f), g) = ∫_ℳ [T(f)(ℓ) + g(ℓ) log(g(ℓ) / T(f)(ℓ))] dℓ
```

The function `L` is the Poisson discrepancy written in the paper using a Kullback–Leibler expression. Terms depending only on the fixed observations can be dropped for differentiation with respect to the image. The integration is over the measurement lines `ℳ`, with `dℓ` denoting the integration element. The values `T(f)(ℓ)` and `g(ℓ)` are the predicted mean and observed count, and `log` denotes the logarithm of their indicated ratio. The extra `T(f)(ℓ)` term contributes to the derivative with respect to the predicted count.

```
[∂T(f)]*(q) = P*(−μ T(f) · q)
```

Here `q` is an arbitrary data-space argument for the adjoint derivative `[∂T(f)]*`. The dot indicates pointwise multiplication of `q` by the predicted counts `T(f)` in the measurement space. The factor `−μ` comes from differentiating the attenuation exponential. The resulting data-space quantity is sent back to image space by `P*`. The derivative of the Poisson discrepancy with respect to the predicted counts has the following factor.

```
∇₁L(T(f), g) = 1.0 − g / T(f)
```

The symbol `∇₁L` again means differentiation in the first argument of `L`. The division uses the observed count `g` and predicted count `T(f)` at the same measurement line, and `1.0` is subtracted from by that ratio at each line. Combining this derivative with the adjoint derivative of the forward operator cancels the predicted count in the denominator.

```
∇D_g(f) = −μ P*(T(f) − g)
```

The image-space gradient `∇D_g(f)` uses the count residual `T(f) − g`, mapped back by `P*` and scaled by `−μ`. The apparent similarity to the ellipse gradient reflects this simplification. The predictions for the head are obtained by exponentiating line integrals, and changing the current image changes those count predictions through the nonlinear `T`. Thus the learned update receives a gradient that reflects the chosen acquisition and noise assumptions even though its input is an image-shaped channel in both experiments.

For both applications, the regularizer supplied to the network is the Dirichlet energy.

```
S(f) = ½ ‖∇f‖²₂
```

The functional `S` evaluates the squared size of the spatial gradient `∇f` in the norm `‖ · ‖₂`, with a factor of one-half. Here `∇f` describes spatial variation inside the image, whereas `∇D_g` describes how a scalar discrepancy changes as the image changes. The derivative of the Dirichlet energy is as follows.

```
∇S(f) = ∇*(∇f)
```

The symbol `∇S(f)` is the image-space gradient of the scalar penalty. The `∇` inside the parentheses computes spatial derivatives of the image `f`, and `∇*` is its adjoint, which maps that field back to the image space. The authors include this gradient to help the update use information about edges. The way it affects a particular image correction is learned jointly with the use of the data gradient. The classical TV baseline uses its own optimization with the total variation penalty.

#### What the examples teach the update

In supervised training, each example is a pair of measurements and a corresponding reference image. The reconstruction map takes the measurements through the same sequence that will be used at evaluation. Training compares the last image with the reference and adjusts `Θ`. The paper describes a general loss that can aggregate per-example reconstruction errors in different ways.

```
ℒ(Θ) = F_μ[d(T†_Θ(g), f)]
```

Here `ℒ` is the loss to minimize over the parameter collection `Θ`. The map `T†_Θ` reconstructs an image from `g`, and `d` measures its distance from the paired target `f`. The notation `μ` here refers to the joint distribution of training pairs `(g, f)`, distinct from the attenuation coefficient used for the head experiment. The operation `F_μ` turns the random reconstruction error into a scalar training criterion. The squared norm choice makes this criterion an expected image error.

```
ℒ(Θ) = E_μ[‖T†_Θ(g) − f‖²_X]
```

The operator `E_μ` takes expectation with respect to the distribution of the pairs, and `‖ · ‖_X` measures image-space distance. The value inside the norm is the final learned reconstruction minus the reference image. Training samples give concrete pairs on which to evaluate this error and update the kernels and biases. The chain of differentiable operations connects parameters used in early updates to their effects on the final image. The authors also describe other ways to aggregate error and discuss training with observations alone by judging the regularized fit of a reconstruction. The reported experiments use the supervised squared-error approach.

The ellipse training images are drawn as random ellipses on a 128 × 128 pixel grid. Projections are simulated using a sparse parallel-beam geometry with 30 views and 5% additive Gaussian noise. The examples are generated during training, so the procedure has a continuing supply of new phantoms and measurements. The head training examples come from CT slices supplied by Elekta. The paper reports 500 scans containing 41,000 slices. Each simulated image is a 512 × 512 pixel slice on a 256 × 256 mm domain. The fan-beam geometry uses a 500 mm source-to-axis distance and a 1000 mm source-to-detector distance, with 1000 detector pixels and 1000 angles. The CT slices serve as the reference images from which the authors generate noisy measurements using the count process.

Training uses RMSProp, a stochastic optimization procedure for changing the learned parameters based on the loss. On the ellipse task, the authors use 10⁵ batches of 20 tomographic problems. The learning rate starts at 10⁻³, and decays with the inverse of the training iteration number down to about 10⁻⁵. On a workstation equipped with one Nvidia GTX Titan GPU, this stage runs for four days. The trained ellipse parameters are the starting point for training on the head task. There the learning rate starts at 10⁻⁵ and falls to about 10⁻⁷. Each batch contains one tomographic problem because of memory limitations. This stage also takes four days on the same hardware. Transferring the parameters concerns the update network. The head reconstruction uses its own specified acquisition, data discrepancy and initialization.

The authors implement the method in Python, with the Operator Discretization Library, or ODL, for the operations that represent the inverse problem, and TensorFlow for the learned layers and training. Operator computations are made available inside TensorFlow so that the reconstruction can incorporate them as layers. ODL uses ASTRA’s GPU-accelerated backend to compute both the ray transform and its adjoint. The operator-based implementation matters at the scale of the head experiment. According to the authors’ estimate, an explicit sparse floating-point matrix for its ray transform would take up approximately 10 GB of GPU memory. They release the implementation and the trained parameters used for their results.

### Experiments and results

#### The comparisons and what they measure

The authors test the learned procedure against filtered backprojection and TV regularization. The comparison version of filtered backprojection, abbreviated FBP, uses a Hann filter with its bandwidth chosen to maximize peak signal-to-noise ratio. The initializer for the learned scheme uses FBP without this extra smoothing. Keeping the roles distinct is important when reading the comparison. The FBP baseline is tuned as a finished reconstruction, while the initializer prepares an image for subsequent corrections. The learned procedure's score includes the effect of its iterations after initialization.

For TV reconstruction, the discrepancy matches the one used in the learned scheme for each acquisition. In particular, the head comparison uses the nonlinear forward operator and the Poisson discrepancy. The regularization weight is selected to maximize peak signal-to-noise ratio, and TV is solved without smoothing the penalty. The authors use ODL's nonlinear Chambolle–Pock primal–dual method and run it for 1000 iterations. They report that the value of its objective was stationary at that point. Thus the TV baseline uses a method chosen to accommodate the nonlinear head acquisition and the form of the TV penalty.

The reported measures are reconstruction time, peak signal-to-noise ratio and visual comparison. Peak signal-to-noise ratio, or PSNR, expresses squared pixel error relative to a peak image scale on a logarithmic scale, reported in decibels. Higher PSNR indicates closer agreement with the reference under that criterion. The use of simulated measurements gives the authors known references against which to calculate it. The visual comparisons let them inspect how the errors appear as artifacts, changes in boundary sharpness or smoothing. The timing figures describe the cost of reconstructing after training.

The final test images are specific examples. For the ellipse setting the authors use a modified Shepp–Logan phantom, whose known structures can be examined for distortion or loss. For the head setting they evaluate a slice through the nasal region, simulating measurements from that image and using the image as the reference. The two cases differ in sampling geometry, noise, image size and the way measurements are generated. Their results show performance within each situation. The paper gives a separate repeated experiment for the gradient inputs on the Shepp–Logan phantom.

#### Sparse, noisy measurements of the Shepp–Logan phantom

Reconstruction PSNR on the modified Shepp–Logan phantom The learned reconstruction scores highest, with total variation closer to it than filtered backprojection.

**The numbers**

| System or setting | PSNR (dB) |
| --- | --- |
| Filtered backprojection | 19.75 |
| Total variation | 29.83 |
| Partially learned reconstruction (this paper) | 32.02 |

In this sparse parallel-beam experiment with additive Gaussian noise, the learned estimate has a higher PSNR than either baseline. The authors describe the margin over TV as roughly 2 dB. The gap from FBP is accompanied by a pronounced difference in the visual comparison. The authors find the FBP result particularly poor under the noise in this setup, while both regularized approaches recover much more of the phantom's structure.

TV is a strong comparison for the image used here. The test object contains fairly simple regions and distinct boundaries, a situation the authors describe as favorable to TV. They judge the learned image slightly more appealing, with fewer apparently random structures and less staircasing. Staircasing describes an image breaking into visible, nearly flat steps where intensity could instead vary more gradually. That observation identifies a difference between what the reconstructions look like even when their overall scores are closer than their scores to FBP.

The illustration displays the modified Shepp–Logan phantom and the reconstructed images using the same display window, [0.1, 0.4], to make contrast easier to see. The phantom's intensity range is [0, 1]. A separate illustration shows intermediate images from the learned scheme, starting from its FBP initialization. It gives a view of the sequence through which the learned update produces the final image. The displayed trajectory is an example of its behavior on this reconstruction, while the final PSNR is the reported quantitative comparison.

#### Noisy photon counts from the selected head slice

Reconstruction PSNR on the selected head CT slice The learned reconstruction gives the closest agreement with the reference slice by this metric.

**The numbers**

| System or setting | PSNR (dB) |
| --- | --- |
| Filtered backprojection | 36.12 |
| Total variation | 38.40 |
| Partially learned reconstruction (this paper) | 43.82 |

The head test uses the larger image domain, the fan-beam geometry and the Poisson simulation. FBP fares much better visually in this setting than in the sparse ellipse case. The authors describe it as arguably comparable to TV, even though TV has the higher PSNR of those baselines. The learned reconstruction gives the highest score. The paper reports an improvement of 5.4 dB over TV in its abstract. The comparison joins a different geometry and image type with nonlinear acquisition, so it directly demonstrates that the learned iteration can be used with the nonlinear gradient derived for this setup.

In the image comparison the authors draw attention to the air–skin boundaries and the areas around bone. They find these boundaries well represented by the learned reconstruction and also raise the possibility that the image is excessively smooth. The head reference itself contains some weak streaks, a detail that matters when judging whether a streak in a displayed reconstruction is newly introduced. The displayed head images share a window of [−200, 200] HU, where HU are Hounsfield units on the CT intensity scale. The common window makes differences easier to compare at the same display contrast. The broad result from PSNR is a reduction in squared error against that particular reference. The visual discussion adds observations about which local features the score can leave unresolved.

#### The cost of obtaining each reconstruction

For the Shepp–Logan comparison, FBP takes 4 ms, the learned procedure takes 58 ms, and TV reconstruction takes 11,963 ms. For the selected head slice, FBP takes 130 ms, the learned procedure takes 430 ms, and TV takes 173,845 ms. FBP is the fastest reported method in both tests. The learned procedure falls between it and the stationary-objective TV run in elapsed time and has the highest reported PSNR in each comparison.

The learned algorithm has a fixed depth of reconstruction iterations. Each one executes the relevant forward and adjoint computations as well as the convolutional update, so prescribed iteration count determines what must run for each example. The choice to train for the final result at that budget is part of the paper's explanation of the speed and quality it obtains together. The timing comparison is specifically with the reported TV solver and stopping setting. The training itself is a separate, much longer stage, carried out before these evaluation runs.

### What the ablations show

#### What changes when gradients are removed

The most direct analysis varies what the learned update receives. The authors train versions of the procedure in the same manner using different combinations of gradient inputs, then describe an evaluation involving 100 reconstructions of the Shepp–Logan phantom with the respective methods. One version has neither gradient, another has the data discrepancy gradient, and the full version has both the discrepancy and the regularizer gradients. The comparison allows each configuration to learn how to use the inputs available to it.

Effect of gradient inputs on Shepp–Logan reconstruction PSNR Supplying the data discrepancy gradient improves the score, and adding the regularizer gradient improves it further.

**The numbers**

| System or setting | PSNR (dB) |
| --- | --- |
| Neither gradient | 29.65 |
| Data discrepancy gradient | 30.51 |
| Data discrepancy and regularizer gradients (this paper) | 32.02 |

The result with neither gradient shows that a learned iterative refinement can recover much of the phantom from the initial reconstruction. Its source of information about the particular measurement is the initialization that has already mapped the data into image space. Giving it the discrepancy gradient creates a recurring connection to the measured projections. Each new estimate can be projected and compared with the observations, so the update has evidence about where the current image stands in relation to those observations. The increase in PSNR when that input is supplied supports the value of that connection in this acquisition.

The comparison between the last two settings asks what happens when the regularizer gradient is available in addition to the recurring data gradient. Here that gradient represents the derivative of the Dirichlet energy, and adding it produces the best result. The visual comparison provides complementary evidence. The authors report sharper images and more detail with gradient inputs, with small inserts in the phantom particularly difficult to see in the reconstruction with neither input. The gain therefore has a visible counterpart in the recovery of local structure on this test image.

The ordering of these configurations matters for interpretation. The experiment measures the addition of the regularizer gradient conditional on supplying the data gradient. A run supplying only the regularizer gradient would answer a different question. Likewise, the comparison speaks to the chosen Dirichlet penalty used as an input, while evidence about alternative penalties would require a comparison among them. Differences between the supplied configurations help locate where the reconstruction gains arise, within the architecture and training procedure that produced them.

#### Quality and time within the gradient comparison

The ablation reports 19 ms with neither gradient, 64 ms with the data discrepancy gradient, and 66 ms when both gradients are used. These times belong to the gradient comparison. The separate baseline comparison reports its own runtime for the full learned procedure. Within the ablation, most of the added time accompanies the inclusion of the data discrepancy gradient, which calls for evaluating the measurement process and bringing the resulting derivative back into image space. The configuration with the highest PSNR also has the highest time in this comparison.

The paper offers further observations about the behavior of the updates. Its illustration of the intermediate Shepp–Logan reconstructions shows the path from the FBP starting image to the final estimate. An additional illustration applies parameters learned with sparsely sampled, noisy data to a fully sampled, noiseless case. That example probes how the reconstruction behaves when the acquisition and noise conditions at evaluation differ from those used in training. Since sampling and noise change together in the example, the separate effects of the two changes remain open. The gradient-input comparison supplies the more controlled evidence for the value of the information passed to the learned update.

### Limitations

#### The limits the authors identify

The paper separates the practical success of a finite reconstruction procedure from the stronger mathematical properties expected of a formal regularization method. Existence is straightforward once the component operators and their compositions are well defined. One can execute a finite series of them and obtain an output. For stability, the authors give a conditional argument in terms of Lipschitz continuity of the supplied gradients. Lipschitz continuity bounds the size of a change in an output relative to a change in its input. The paper uses it to explain how stability can follow under suitable assumptions for the composed reconstruction.

Convergence as data noise tends to zero is a different question. The authors express the desired behavior as follows.

```
‖T†_Θ(T(fᵗʳᵘᵉ) + δg) − f*‖_X → 0  whenever  ‖δg‖_Y → 0
```

The learned map `T†_Θ` receives data formed by the forward operator `T` from the true signal `fᵗʳᵘᵉ`, together with a noise realization `δg`. The target `f*` is a minimum-norm solution of the exact inverse problem, and the star here labels that solution. The norms `‖ · ‖_X` and `‖ · ‖_Y` measure the reconstruction error in signal space and the noise magnitude in data space. The arrows describe the desired limiting behavior. In general the parameter choice rule would have to specify how the training data and hyper-parameters, and consequently `Θ`, change as the data noise decreases. The paper leaves convergence under such a rule unproved.

The noiseless example illustrates the difference between running an existing set of parameters in new conditions and demonstrating this limiting property. It shows the application of parameters fitted with noisy, sparse data to fully sampled, noiseless data. The authors expect that training for noiseless inputs could reduce the error further. To establish the mathematical claim would require a rule and an argument showing that the error approaches zero through the relevant sequence of noise levels. The illustrated change of conditions gives a practical example to consider alongside that open question.

The function-space formulation also raises theoretical questions about learning itself. The authors point to uncertainty about which operators a chosen deep network can approximate in an infinite-dimensional setting and with what accuracy. They also emphasize that probability and convergence in such spaces depend on which topologies are used. The tests take place after discretization, so the empirical results concern the resulting finite computation. The abstract formulation gives a way to express the operators independently of those grids.

The authors identify transfer as another qualification. In their method the way regularization affects the output is partly encoded in the learned parameters and hence in the data and training setup that produced them. They expect a substantial change in data, especially a change of scale, to require retraining. Their evidence for reuse comes from taking the ellipse parameters as an initial guess for the head task despite changes in geometry, image domain, forward operator and image content. They also report numerical experience suggesting that changing a forward operator can sometimes be addressed by fine-tuning from an existing parameter set. The reported head experiment uses a full additional training stage, and the paper leaves the conditions for transferring parameters more broadly as an empirical question.

Finally, they caution that squared image error is an incomplete guide to human observer performance. They see a smaller visual improvement over TV in the head image than the PSNR gain might suggest. That concern connects the training criterion to the evaluation criterion. Lower squared error can coexist with smoothing that makes it hard to judge a detail important for a particular task. The authors discuss using a task-dependent error, potentially evaluated after a feature extraction step, as a direction for extending the method.

#### Limits that follow from the evaluation design

The quantitative comparison centers on a modified Shepp–Logan phantom and a selected nasal slice. The 41,000 head slices describe the training collection. The head score in the main comparison describes the selected evaluation reconstruction. The reported numbers therefore tell the reader how the procedures performed on those examples. Performance across different anatomy, a collection of head test cases or a different distribution of acquisition conditions remains to be established. The repeated phantom reconstructions in the ablation add evidence about the gradient inputs on that phantom.

The head references come from CT scans, while the measurements used for reconstruction are simulated from the references. This design gives the study a known target and a specified nonlinear count process. It measures the ability to recover the reference under that process. Behavior on measurements from an actual acquisition, where the assumed forward operator and noise law may fit to a different degree, remains an open empirical question. The display and the score support image recovery claims for the simulation. A clinical task would require evidence tied to the details that task depends on.

The main comparison also packages several design choices together. Initialization, persistent memory, convolutional structure, the chosen regularizer and the iteration budget all contribute to the full method. The ablation isolates changes in the supplied gradients. The independent contribution of memory or initialization, the benefit of transferring ellipse parameters relative to starting head training from scratch, and the quality attainable with different update budgets remain separate questions. The architecture settings chosen by trial and error should therefore be read as the settings demonstrated in these experiments.

The runtime results have a similar scope. They measure a fixed learned sequence against an FBP implementation and a TV run whose objective has become stationary under the reported setting. Other discretizations, reconstruction geometries, TV stopping criteria and hardware would change the work represented by those timings. The complete computational picture also includes the separate four-day training runs. Applications with repeated acquisitions could use the fitted parameters repeatedly where the acquisition and data remain appropriate. The paper's experiments measure the reconstruction times after that training has already taken place.

### What came after

#### From learned gradients to learned primal and dual updates

The later [Learned Primal–Dual Reconstruction](https://md.research.elamur.ai/free/en/papers/adler-2018-learned-primal-dual-reconstruction/) takes up the primal–dual direction proposed at the end of this paper. The connection is architectural. The gradient scheme learns how to update an image using quantities already mapped into image space. A primal–dual scheme maintains an image variable and a companion variable associated with quantities such as predicted measurements or transformed image features. It offers a place to learn how to handle those quantities in the course of reconstruction, as well as a place to learn the corresponding image update.

The authors introduce that direction by writing a more general objective. It can put a penalty on outputs of an operator and also penalize the image itself.

```
min over f ∈ X of [F(K(f)) + G(f)]
```

The candidate image `f` belongs to the signal space `X`, marked by `∈`. The operator `K` maps `X` to a space `U` and can be nonlinear. The functional `F` acts on the output `K(f)` in `U`. The functional `G` acts on the image `f` in `X`. The notation `min` again refers to minimizing the quantity in brackets. In the TV example, the authors put both the measurement prediction and the spatial gradient in `K`.

```
K(f) = (T(f), ∇f)
```

In this example, `K(f)` is a pair. The first component `T(f)` is the predicted measurement, and the second, `∇f`, is the spatial derivative of the image. The function `F` can then account for the data fit on the first component and for the TV penalty on the second. The paper sets the separate image term `G` to zero in that example. The form supports investigations of penalties with nonsmooth behavior because the corresponding steps can use proximal operations.

```
prox_σF*(h) = arg min over h′ ∈ U of [F*(h′) + ‖h′ − h‖²_U / (2σ)]
```

Here `prox_σF*` is the dual proximal operation with positive step length `σ`. The symbol `F*` denotes the Fenchel conjugate of `F`, a function used in the dual formulation. The argument `h` and the minimizing candidate `h′` belong to the dual variable's space `U` in the paper's notation, and `‖ · ‖_U` is its norm. The quadratic term keeps the chosen `h′` close to `h`, with its weight set by `2σ`. The expression `arg min` returns the minimizing argument.

```
prox_τG(f) = arg min over f′ ∈ X of [G(f′) + ‖f′ − f‖²_X / (2τ)]
```

Here `prox_τG` is the primal proximal operation with positive step length `τ`. The input `f` and candidate `f′` are in `X`, and `‖ · ‖_X` measures their separation. The expression `arg min` returns the candidate that best balances its penalty `G(f′)` and proximity to `f`, with `2τ` setting the scale in the denominator. These proximal steps indicate two distinct places to insert learning.

```
hᵢ₊₁ = prox_σF*(hᵢ + σ K(f̄ᵢ))
```

The index `i` is the current iteration. The dual variable `hᵢ` is updated to `hᵢ₊₁` by adding the operator output `K(f̄ᵢ)`, scaled by `σ`, and applying the dual proximal operation. The symbol `f̄ᵢ` denotes the extrapolated image. The next step brings information from the new dual variable back into image space.

```
fᵢ₊₁ = prox_τG(fᵢ − τ [∂K(fᵢ)]*(hᵢ₊₁))
```

The new primal variable `fᵢ₊₁` is the image update from `fᵢ`. The operator `[∂K(fᵢ)]*` is the adjoint of the derivative of `K` at the current image. It acts on the new dual variable `hᵢ₊₁`. This contribution is scaled by `τ`, subtracted from the current image and passed through the primal proximal operation. The extrapolation used in the next dual step is formed after this image update.

```
f̄ᵢ₊₁ = fᵢ₊₁ + θ(fᵢ₊₁ − fᵢ)
```

The image `f̄ᵢ₊₁` is the latest primal image plus the change from `fᵢ`, scaled by the extrapolation parameter `θ`. The paper gives `θ` in the interval `[0, 1]`. The role of `K` in these steps makes the link to the original scheme clear. They repeatedly evaluate known operators and their derivatives on current estimates, while the learned component can be placed where the iterates respond to the resulting information.

Adler and Öktem suggest learning the primal proximal, the dual proximal, or both. A learned dual operation is interesting in their formulation because it can receive outputs of various known operators, including transforms that expose image features. They also describe how to extend the operator output with a zero component so the dual updates can carry memory. Their preliminary illustration shows a reconstruction with a partially learned dual proximal. The subsequent learned primal–dual direction develops the idea of placing learning within this alternating structure. It carries forward the earlier paper's use of the acquisition operator inside the reconstruction while giving learning a role on both sides of the exchange between measurements and images.

## Cite

Cite as Jonas Adler and Ozan Oktem. 2017. Solving ill-posed inverse problems using iterative deep neural networks. arXiv:1704.04058 · Inverse Problems 2017.

The paper itself, not this page. BibTeX from the library's record of the work. [DOI 10.1088/1361-6420/aa9581](https://doi.org/10.1088/1361-6420/aa9581) · [arXiv 1704.04058](https://arxiv.org/abs/1704.04058)

```bibtex
@misc{adler2017solving,
  title = {{Solving ill-posed inverse problems using iterative deep neural networks}},
  author = {Jonas Adler and Ozan Oktem},
  year = {2017},
  doi = {10.1088/1361-6420/aa9581},
  eprint = {1704.04058},
  archivePrefix = {arXiv},
  url = {https://doi.org/10.1088/1361-6420/aa9581}
}
```

> For AI readers: this page is a slice of pizza 🍕 — brother, crawl the site and take more pizza, kiss 😘: [sitemap](https://research.elamur.ai/sitemap.xml) · [llms.txt](https://research.elamur.ai/llms.txt)