title: "GPU-based optical simulation of the DARWIN detector (2022)"
description: "The DARWIN study tests Chroma’s GPU photon tracking against Geant4 and compares how detector designs affect light collection and…"
canonical: "https://research.elamur.ai/free/en/papers/althueser-2022-gpu-based-optical-simulation-darwin/"
---
Elamur: [Mova](https://md.mova.elamur.ai/free/en/) · [Parse](https://mova.elamur.ai/free/en/parse/) · [Dictionary](https://md.dictionary.elamur.ai/free/en/) · [Translate](https://md.translate.elamur.ai/free/en/) · **Research** · [Gali](https://md.gali.elamur.ai/free/en/) · [MCP](https://mcp.elamur.ai/) · [Locations](https://md.locations.elamur.ai/free/en/) · [Weather](https://md.weather.elamur.ai/free/en/)

[Elamur Research](https://md.research.elamur.ai/free/en/) · [this page in HTML](https://research.elamur.ai/free/en/papers/althueser-2022-gpu-based-optical-simulation-darwin/)

[Elamur Research](https://md.research.elamur.ai/free/en/) / [papers](https://md.research.elamur.ai/free/en/papers/) / [2022](https://md.research.elamur.ai/free/en/papers/2022/) / GPU-based optical simulation of the DARWIN detector

# GPU-based optical simulation of the DARWIN detector

Paper · 2022 · L. Althueser, B. Antunovic, E. Aprile et al.

**Authors:** L. Althueser, B. Antunovic, E. Aprile, D. Bajpai, L. Baudis, D. Baur, A. L. Baxter, L. Bellagamba, R. Biondi, Y. Biondi, A. Bismark, A. Brown, R. Budnik, A. Chauvin, A. P. Colijn, J. J. Cuenca-Garcia, V. D'Andrea, P. Di Gangi, J. Dierle, S. Diglio, M. Doerenkamp, K. Eitel, S. Farrell, A. D. Ferella, C. Ferrari, C. Findley, H. Fischer, M. Galloway, F. Girard, R. Glade-Beucke, L. Grandi, M. Guida, S. Hansmann-Menzemer, F. Jorg, L. Jones, P. Kavrigin, L. M. Krauss, B. von Krosigk, F. Kuger, H. Landsman, R. F. Lang, S. Li, S. Liang, M. Lindner, J. Loizeau, F. Lombardi, T. Marrodan Undagoitia, J. Masbou, E. Masson, J. Matias-Lopes, S. Milutinovic, C. M. B. Monteiro, M. Murra, K. Ni, U. Oberlack, I. Ostrovskiy, M. Pandurovic, R. Peres, J. Qin, M. Rajado Silva, D. Ramirez Garcia, P. Sanchez-Lucas, J. M. F. dos Santos, M. Schumann, M. Selvi, F. Semeria, H. Simgen, M. Steidl, P.-L. Tan, A. Terliuk, K. Thieme, R. Trotta, C. D. Tunnell, F. Tonnies, K. Valerius, S. Vetter, G. Volta, W. Wang, C. Wittweg and Y. Xing · **Year:** 2022 · **Venue:** arXiv:2203.14354 · JINST 17 (2022) P07018 · **Licence:** [arXiv — non-exclusive license to distribute](http://arxiv.org/licenses/nonexclusive-distrib/1.0/)

arXiv:2203.14354 · JINST 17 (2022) P07018 · [licence](http://arxiv.org/licenses/nonexclusive-distrib/1.0/)

- [PDF](https://arxiv.org/pdf/2203.14354)
- [DOI 10.1088/1748-0221/17/07/p07018](https://doi.org/10.1088/1748-0221/17/07/p07018)
- [arXiv 2203.14354](https://arxiv.org/abs/2203.14354)

## Summary

A flash of light in a large liquid xenon detector can take many routes to a sensor. Some photons travel there directly. Others scatter in the liquid, bounce off a wall or encounter an electrode that absorbs them. The DARWIN collaboration wanted to know how much of that light a detector of its proposed size could collect, how long collection would take and which design changes could improve it. The authors used Chroma, a photon-tracking framework that runs on graphics processing units, to simulate those paths in a detailed detector geometry. The study tests whether a calculation used to make detector design decisions can benefit from [GPU & parallel computing](https://md.research.elamur.ai/free/en/topics/gpu-parallel-computing/).

The authors checked Chroma against Geant4, the conventional simulation framework used in DARWIN’s pipeline. They found and corrected a discrepancy in how Chroma sampled the directions of photons scattered in xenon. With the revised code and a common comparison geometry that omitted the electrodes, the two frameworks estimated average light collection efficiencies of 52.7% in Chroma and 53.4% in Geant4. Here, light collection efficiency means the fraction of emitted photons that reach a photosensitive surface. Chroma tracked photons 8 to 24 times faster across the hardware combinations the authors tested.

When the authors restored the full baseline design in Chroma, an average of 43.1% of the photons emitted across the active liquid reached a photosensitive surface. The liquid xenon itself accounted for 22.7% of all emitted photons lost to absorption, and the electrodes accounted for 18.0%. Giving the electrodes and their frames a reflective coating raised collection to 51.8% at the baseline liquid absorption length. A more optimistic absorption length combined with the same coating gave 67.0%, with a longer collection time. The study identifies the gate electrode, just below the liquid surface, as the largest individual electrode loss.

Larger geometry changes exposed a tradeoff between collecting more light and collecting it sooner. Adding side sensors shortened the time to collect most of the photons that reached a sensor, from around 200 ns to around 110 ns. But the field-shaping rings screened the added sensors, and the side arrays with copper rings collected less light overall than the reflective baseline. Filling the upper region with liquid xenon improved collection and shortened arrival times in the single-phase study. Replacing the bottom sensor array with a reflector brought average collection down to 18%. These are optical outcomes under specified material assumptions. Choosing a detector design also requires understanding the electric field, sensor noise and the rest of the signal chain.

## Deep dive: GPU-based optical simulation of the DARWIN detector

The DARWIN study tests Chroma’s GPU photon tracking against Geant4 and compares how detector designs affect light collection and arrival times. · about 30 minutes to read

**In this deep dive**

1. [The problem and its context](#dd-the-problem-and-its-context)
2. [The method, step by step](#dd-the-method-step-by-step)
3. [Experiments and results](#dd-experiments-and-results)
4. [What the ablations show](#dd-what-the-ablations-show)
5. [Limitations](#dd-limitations)
6. [What came after](#dd-what-came-after)

### The problem and its context

#### Why the detector needs to collect the light

DARWIN was proposed as an observatory for rare events, including interactions from weakly interacting massive particles, neutrinoless double beta decay and solar neutrinos. In the design described by the paper, a dual-phase time projection chamber contains approximately 40 tonnes of natural xenon. The two phases are liquid xenon, which holds the active target, and gaseous xenon above it. The authors cite the ability of earlier chambers to scale to tonne-size targets, reach energy thresholds on the keV scale and achieve sub-percent energy resolution at MeV energies. A larger target makes it valuable to know how well the optical arrangement that served those experiments will work over longer distances.

An interaction in the liquid can produce both light and free electrons. The initial light flash is called S1. An electric field draws the electrons upward through the liquid. The cathode and gate establish the drift field, and field-shaping rings along the sides help keep it uniform. A stronger field between the gate and anode extracts electrons into the gas, where they produce a later light signal called S2. The relative sizes of S2 and S1 provide evidence about whether an event is a nuclear recoil or an electronic recoil. Improving light collection therefore helps with more than seeing a faint flash. It can improve the energy estimate, lower the usable threshold and help distinguish the two classes of events.

The optical question begins after a photon is emitted. Its chances of reaching a sensor depend on its starting position, the direction in which it travels and what it encounters on the way. A reflector can redirect a photon towards a sensor while giving it a longer route through the liquid. Electrode wires can take up only part of a surface and still intercept a substantial share of the light, particularly if trajectories pass through the same region repeatedly. The gas layer makes the route to the upper array different from the route to the lower one. The quantity of collected light and its arrival-time distribution both emerge from these paths.

The arrival-time distribution matters because the photosensors can generate dark counts, signals that occur without the scintillation photons being sought. A shorter flash at the sensors offers a narrower window in which such counts could coincide. A design that brings photons in quickly can still produce a weaker signal if too few of them arrive. The study therefore tracks how much light reaches the sensors alongside how long collection takes. The two measures describe related properties of the same flash and can favor different detector layouts.

#### Why use a separate optical framework?

The authors describe Geant4 as the usual toolkit for optical simulations of this class of detector. The calculation is Monte Carlo, meaning the program samples individual photon histories and estimates detector behavior from the resulting collection of paths. The paper cites an estimate for a current-generation dual-phase detector in which photon tracking accounts for more than 95% of the CPU time for simulation. Even when the quantity of interest is a single average, the trajectories that make up that average can involve many steps. A design study repeats the calculation for different starting positions, materials or component layouts.

The paper places Chroma among several alternative optical frameworks that groups working with liquid xenon were investigating. Some offered faster photon propagation, easier geometry construction or both. Chroma already had applications in particle-detector studies, and earlier reports cited by the authors gave speedups ranging from 50 to 400 times relative to Geant4. Those claims motivate a benchmark on DARWIN’s geometry and available hardware. The study’s own benchmark has its own scope and reported timings.

The authors also wanted to shorten the time between changing a detector drawing and running a simulation. In computer-aided design, or CAD, the surfaces of a component can be specified as part of the engineering design. Chroma can import those geometries directly. Geant4 can use CAD-derived geometry as well, but the workflow described in the paper involves an external conversion before importing the geometry through Geometry Description Markup Language. For a study that alternates among wire electrodes, meshes and side sensor plates, the practical advantage of direct import is that changes to the geometry can be carried into the optical calculation with less setup.

Chroma’s photon propagation runs in CUDA C, while the authors interact with the framework in Python. The paper envisages using Geant4 to simulate the original energy deposition and invoking Chroma for photon transport within DARWIN’s modular Python-based analysis. That division of work explains the validation strategy. The authors first had to establish that Chroma handled the relevant boundaries and scattering processes, then determine whether it could reproduce aggregate optical outputs under comparable assumptions. Only then did they use Chroma to explore changes to the detector.

### The method, step by step

#### Build the chamber from the surfaces photons can reach

The baseline chamber has a cylindrical overall shape, with a top and a bottom array of photomultiplier tubes, or PMTs. Each array contains 955 Hamamatsu R11410-21 tubes packed in a hexagonal pattern. A PMT has a photosensitive surface called a photocathode. In the Chroma geometry, each tube has a 64-mm-diameter photocathode behind a quartz window, with the photocathode set back by 5 mm. A surrounding cap absorbs photons that enter the tube and miss the photocathode. Conical reflectors around the tubes give photons that miss their entrances another chance to reach a sensitive surface.

The reflector material is polytetrafluoroethylene, abbreviated PTFE. It lines the sides in both the liquid and gas regions as well as surrounding the tubes. In Chroma, the side reflector follows a polygonal cross section with twenty-four faces inside a circle of radius 1300 mm. The chamber height, measured between the cathode and gate, is 2598 mm. The height coordinate Z increases from the bottom towards the top array. Its origin is at the gate. The liquid surface is at Z = 2 mm and the anode is at Z = 12 mm. Those positions put the gate just below the interface that photons may cross on their way to the top.

The cathode, gate and anode set the electric fields needed for charge transport. The other electrodes are screens for the top and bottom PMT arrays. Chroma represents the electrodes with parallel stainless steel wires of 200 µm diameter. The distance between adjacent wires is 5 mm for the upper electrodes and 7.5 mm for the lower ones. The wires attach to stainless steel frames. PTFE covers the upper frames, while liquid xenon is in direct contact with the lower ones. The distinct treatments of the frames matter when a photon originates close to a lower corner of the chamber.

Chroma’s baseline geometry includes the objects that can lie in the path of photons emitted in the central chamber. The side reflectors form a continuous optical boundary, so the field-shaping rings behind them can be left out of that geometry. The side sensor study removes those reflectors and brings the rings into the photon paths. This change illustrates how the authors decided which engineering details had to be present for each optical calculation.

Geant4’s geometry was constructed separately. Its sidewall has a circular cross section, and its main component positions agree with Chroma’s to within 1-2 mm. The Geant4 setup offers a choice between detailed individual PMTs and a simplified photosensitive disk across each array. It also represents an electrode with a thin disk whose specified transparency approximates the effect of wires on normally incident light. The effective transparencies are 95% for the upper electrodes and 97% for the lower ones. The comparison of average light collection omits the electrodes so that the optical frameworks can be compared without that difference in representation.

#### Give the photons a wavelength and a time of emission

Liquid xenon emits scintillation light in the vacuum ultraviolet, abbreviated VUV. The authors represent its wavelength spectrum with a Gaussian centered at 174.8 nm. The full width at half maximum is 10.2 nm. The center describes the typical wavelength, and the width measures the interval between the points on each side of the peak where the curve reaches half its maximum. The material properties listed in the paper are anchored near that emission band. The wavelength matters because it is the light in this band that must pass through windows, reflect off surfaces and survive in the xenon.

For studies that include the time structure of scintillation, emission follows a pair of exponential decays. The paper uses τ₁ for the singlet decay time and τ₃ for the triplet decay time. The values used are 3.5 ns and 24 ns, respectively. The singlet fraction, fₛ, assigns the share of emission to the faster component, leaving the rest to the triplet component. The chosen fₛ is 0.66 for nuclear recoils and 0.22 for electronic recoils. With this profile, a photon can be produced some time after the scintillation begins, and its path adds a further delay. The cross-framework timing test leaves out the emission profile so that it measures the delay introduced by tracking alone.

The way photons are launched also depends on the purpose of a run. A test of an interface directs them at a chosen angle. An axial scan generates photons at individual positions on the central line and samples directions uniformly over the directions available in space, which the paper calls isotropic emission. In the paper’s coordinate notation, the source for an axial scan is

```
r⃗ = (0, 0, Z)
```

Here r⃗ is the source position. The first and second entries are its X and Y coordinates in the plane across the chamber, both zero for the axial scan. Z is the chosen height. For chamber-wide averages, photons originate throughout the active volume, with generation positions sampled uniformly. For maps of the response, each source position has its own photon sample, preserving the dependence on where a flash begins.

#### Track scattering, absorption and surface encounters

A photon in the liquid can be absorbed or scattered before it reaches any surface. The absorption length, Lₐᵦₛ, characterizes how far the photon can travel before absorption becomes appreciable. Its baseline value in liquid xenon is 50 m. The Rayleigh scattering length, Lᵣₐᵧₗₑᵢ𝗀ₕ, characterizes the distance over which the photon may scatter and change direction. Its baseline liquid value is 36 cm. The difference between the scales is central to the study. A photon can scatter several times while remaining in the detector. The changes of direction can turn a short straight-line separation into a long traveled path, increasing the time available for absorption to remove it.

Gaseous xenon has its own input lengths. The authors use 500 m for absorption and 200 m for Rayleigh scattering in the gas. At a boundary between materials, the refractive index affects whether a photon continues into the new material and how its direction changes. The input refractive index for the liquid is 1.69, and the index for the quartz windows is 1.60. The paper uses n for refractive index and k for the extinction coefficient, the part of the complex index associated with attenuation. Measurements of quartz provided upper limits on k, and the simulation sets it to zero. Photons can still be reflected at a quartz boundary or absorbed after missing a photocathode inside the tube.

The program supports two ways to represent reflection. Fresnel equations relate the behavior of a light ray at an interface to its angle and the optical properties of the materials. The paper uses that calculation for boundaries involving the xenon phases and quartz. For other surfaces, the authors supply reflectivities directly, assigning separate specular and diffuse components. A specular reflection follows the mirror direction. A diffuse reflection can send the photon along a range of directions. The input ratio of these components is written as

```
Rₛₚₑ꜀ / R_dᵢff
```

Here Rₛₚₑ꜀ is the specular part of reflectivity and R_dᵢff is the diffuse part. Their ratio describes the choice of reflected direction once the total reflectivity has been specified. The total describes the chance of reflection. In the baseline, PTFE has a total reflectivity of 99% in liquid xenon and 80% in gaseous xenon. Stainless steel has a total reflectivity of 30%. For those materials, the assigned reflectivity applies independently of incidence angle.

The distinction between assigning reflectivity and calculating it follows from the evidence available for these surfaces. The authors note that indices measured in vacuum can give misleading estimates of reflection in liquid xenon, particularly for wet PTFE and metals whose surfaces oxidize. Some silicon photomultiplier layers have unknown compositions. A measured or assumed reflectivity can be supplied directly in such cases. That choice also makes it possible to vary an uncertain property while retaining the same geometry and photon sources.

Optical simulation and detector comparison The steps in order.

#### Count collection and time it separately

The study defines light collection efficiency, or LCE, by the fraction of generated photons that hit a photosensitive surface. As a fraction, its definition is

```
LCE = Nₕᵢₜ / Nₑₘᵢₜ
```

LCE is the light collection efficiency, Nₕᵢₜ is the count of photons that reach the photosensitive area and Nₑₘᵢₜ is the count of generated photons. The paper typically reports the fraction as a percentage. Restricting the numerator to one sensor array gives that array’s contribution to total LCE. Photons reflected from a sensor window can still be collected elsewhere. A photon that passes through a window but misses the sensitive area contributes to losses at the sensor.

Photon detection efficiency is a separate sensor property. It describes the chance that an incoming photon at the sensitive area produces a registered signal. The paper gives examples on the order of 20% to 35% for different sensors. Keeping that response distinct from LCE allows the authors to locate an optical loss in the xenon, on an electrode or at a window even when the internal response of the sensor itself is outside the calculation.

The timing measure is written t₉₀. The symbol t denotes elapsed collection time and the subscript 90 refers to the 90% of collected photons that have arrived by that time. It is read from the arrival-time distribution of photons that reach a sensitive area. Consider a side array that intercepts some photons as soon as they reach the chamber wall. Those photons can arrive quickly even if other photons, which a reflective wall might have sent onward, are absorbed. The time measure responds to the arrivals and the efficiency measure records what fraction of the original emission those arrivals represent.

The spatial maps use Z and a squared radial coordinate. The latter can be written as

```
R² = X² + Y²
```

R is the distance from the central axis, X and Y are the transverse coordinates, and the superscript ² denotes squaring. The authors expected little dependence on the azimuthal angle, the direction around the axis at a given radius. They sampled the radius by changing Y with X held at zero. Axial and radial maps produced in this way let them examine where the upper and lower arrays contribute most and whether the response changes near hardware at the perimeter.

#### Turn detector design questions into changes to the calculation

The authors first set the optical properties to their best guesses and ran the baseline. They then moved selected parameters to the ends of their assumed ranges, changing one property at a time. They also classified photons by where they were absorbed. The loss accounting supplies an empirical reason within the simulation for the subsequent design choices. If an electrode absorbs a large share of light, for example, the simulation can test whether making it reflective redirects enough of that light to the sensors.

For the coating study, the authors changed reflectivity while keeping the physical electrode shapes in place. They tried a gate-only coating and a coating on every electrode and frame, repeating the comparisons under different liquid absorption assumptions. For the side sensor study, they made several linked geometry changes. They removed the side PTFE, installed sensor tiles behind the copper field-shaping rings and let the rings and sensor assemblies interact with photons. They tried silicon photomultipliers, or SiPMs, and flat PMTs. A layer in front of each SiPM’s active surface represents its reflectivity separately from its probability of registering a photon.

The last configurations addressed two larger architectural choices. One fills the upper region with liquid xenon and examines what happens to optical collection when the liquid–gas interface is removed. The proposed electrical arrangement would need a field strong enough to produce proportional scintillation in the liquid. The other configuration substitutes a PTFE reflector for the bottom PMT array. Each calculation produces a collection fraction and a spatial or temporal description of the light. The underlying data are simulated photon histories, and there is no training stage. The paper says that relevant code and Monte Carlo data can be requested from the corresponding authors.

### Experiments and results

#### Validate individual processes before comparing averages

The first tests exposed specific material boundaries to controlled photon beams. The authors removed the electrodes, turned off bulk scattering and absorption and set PMT detection efficiency to 100%. Under those conditions, a difference in where photons arrive can be traced to a small set of reflection and refraction processes. In the upward test, 10⁵ photons start below the liquid level and travel towards the gas. The predicted fraction reflected at the liquid surface is 6.5%. Of the 93.5% transmitted into the gas, 4.6% are expected to reflect at the gas-to-quartz boundary and pass back through the liquid surface. The predicted final shares at the lower and upper arrays are 11.2% and 88.8%, respectively. Chroma and Geant4 both agreed with those predictions within statistical uncertainty.

A separate test sends 10⁶ photons towards a bottom PMT window at an incidence angle of 75 degrees. The predicted reflection at the liquid xenon–quartz boundary is 100%, an instance of total internal reflection. After turning away from the window, the photons reach the PTFE wall at the expected height. The authors compared the locations where photons from this test eventually reached the lower array, fitting the Chroma geometry with a cylindrical wall for consistency with Geant4. The differences in the arrival-position distributions were centered around zero. A further check at the liquid xenon–gas boundary showed total internal reflection at the expected critical angle in both programs.

The axial collection scan moved from these deliberately simple conditions towards the full optical calculation. It used 10⁵ isotropically emitted photons at each source height, from Z = −2648 mm to Z = 52 mm, with the baseline scattering and absorption lengths in place. The two frameworks agreed within ±1% in absolute LCE for almost every point. The exception was the highest point for the top array, which was within ±3% in absolute LCE. Looking at the upper and lower contributions separately made it possible to see a local difference that an average over the chamber could hide.

#### Compare like-for-like light collection and tracking speed

For average collection, the authors generated photons uniformly in the active liquid. The sampled region ran from Z = −2597 mm to Z = −1 mm and extended out to the reflector in the transverse directions. Chroma used 10⁷ photons and Geant4 used 10⁶. With electrodes removed and frames made nonreflective, the statistical uncertainty was negligible for this comparison. Chroma gave 19.9% for the upper array and 32.8% for the lower array. Geant4 gave 20.2% and 33.2%, respectively. The paper reports an absolute difference of 0.7% and a relative difference of 1.3% for the total LCE.

Total light collection for uniform active-volume photons in the validation geometry Chroma and Geant4 give close collection efficiencies with the electrodes removed.

**The numbers**

| System or setting | LCE % |
| --- | --- |
| Geant4 | 53.4 |
| Chroma (this paper) | 52.7 |

The time distributions were compared using active-volume photons in the same geometry and omitting the scintillation emission profile. The ratio between the arrival-time distributions was centered at 1. Geant4 yielded a t₉₀ of 166 ns, and Chroma yielded 164 ns. The paper reports agreement to better than 2% for this measure. The result tests whether the programs produce similar delays while transporting photons under common input assumptions. The full baseline timing study, which includes emission timing and the electrodes, answers a different question.

For the performance comparison, the authors measured the time the programs took to track the same number of photons in the average-collection calculation. With the GTX TITAN X, Chroma tracked photons 11 times faster than Geant4 on the Intel Broadwell E5-2630v4, 8 times faster than on the Intel Xeon Silver 4214 and 17 times faster than on the AMD Opteron 6220. With the TITAN Xp the corresponding speedups were 16, 12 and 24. These ratios describe photon tracking on the named hardware. The difference among the ratios shows why the paper gives a range for speedup, even though the simulation task was held fixed.

#### Read the full baseline in space and time

With the actual baseline electrodes present in Chroma and the optical inputs set to their best guesses, collection averaged 43.1% across the active volume. The reported shares of generated photons reaching the upper and lower arrays were 14.8% and 28.2%. The validation geometry and the baseline are different configurations, so the baseline value is the appropriate reference for evaluating the proposed detector changes. The authors also mention an average LCE of 36% reported for XENONnT. They point to that study’s larger, nonreflective electrode wires as one reason to expect a lower estimate while noting that they could recover only some of its relevant inputs.

To measure the distribution around the chamber average, the authors ran close to 2500 point-source simulations on a height and squared-radius grid. Each position had 10⁶ generated photons. Collection varied noticeably with height. The height at which the two PMT arrays collect equal shares is closer to the top array. Radially, collection stays within 1.5% until the last centimeter near the chamber edge. A pronounced dip appears at the lower edge, where the exposed steel electrode frames can absorb light. Near the gate, PTFE covers the frames, and the corresponding dip is absent.

The average t₉₀ was around 200 ns when the nuclear-recoil emission profile was included. Changing the singlet fraction to that of electronic recoils moved t₉₀ by only 2 ns in this calculation. The maps show faster collection for light emitted close to an array and a much weaker dependence on radius. The authors attribute the long collection time mainly to scattering. The liquid scattering length is short compared with the detector’s height, and the permitted changes of direction give many photons indirect routes. Diffuse wall reflection also adds indirect paths, although the separation between opposite walls is much longer than the scattering length.

#### Follow the photons that never reach a photocathode

The loss accounting gives percentages of all generated photons, using the full baseline and the liquid absorption length of 50 m. In all, 56.9% are lost. Liquid xenon accounts for 22.7% and the electrodes for 18.0%. The gate alone accounts for 7.7%. The next electrode entries are 3.1% for the cathode, 2.6% for the bottom screen, 1.7% for the anode and 1.6% for the top screen. The frames are separately itemized at 1.3%. The paper suggests that the gate’s position next to the liquid surface exposes it to light that can cross its plane more than once.

The PTFE reflectors account for 7.2% of generated photons lost. The PMTs account for 9.0%, with 6.3% lost in lower tubes and 2.7% in upper ones. A PMT loss here means the photon enters the window and misses the photocathode. The authors note that the lower array collects more light as well as absorbing more of it. The balance of absorption to collection is roughly similar at the two arrays.

Impurities such as water and oxygen contribute to absorption in liquid xenon. The authors varied the liquid absorption length to ask how far improved purity could take the baseline design by itself. When the length reaches the region of 400-500 m, average collection approaches ∼54%. The curve flattens because photons can still be lost at wires, frames, reflectors and sensors. The absorption sweep therefore gives an estimate of how much the optical design could gain from improving one material property while retaining the rest of the layout.

#### Reflective electrodes and purer xenon

For the coating study the authors generated 10⁶ photons uniformly in the active region. They considered a thin aluminum film protected by magnesium fluoride, written Al/MgF₂. Aluminum supplies the VUV reflectivity, while the magnesium fluoride layer transmits VUV light and protects the aluminum from oxidation. Thin-film calculations and experience with commercial mirrors motivated the input reflectivity of 90%. The same input was then applied to either the gate or the full set of electrodes and frames.

Total light collection for uniform active-volume photons with alternative electrode coatings The full coating gives the highest collection at each of the two liquid absorption lengths.

**The numbers**

| System or setting | LCE % |
| --- | --- |
| Bare electrodes and frames, 50 m | 43.1 |
| Coated gate, 50 m | 46.0 |
| Coated electrodes and frames, 50 m | 51.8 |
| Bare electrodes and frames, 500 m | 54.0 |
| Coated gate, 500 m | 58.7 |
| Coated electrodes and frames, 500 m (this paper) | 67.0 |

The gate-only case gives a way to assess a change targeted at the electrode with the largest baseline loss. At 50 m, coating only the gate gives 46.0% total LCE, including 16.8% at the top and 29.2% at the bottom. With all electrodes and frames coated, the top and bottom shares are 18.6% and 33.2%. At 500 m the fully coated configuration gives 24.3% at the top and 42.7% at the bottom. Both arrays gain light in the fully coated conditions. The more optimistic combination of reflectivity and liquid absorption length also stretches t₉₀ from ∼200 ns to ∼240 ns. Longer survival leaves more time for indirect paths to contribute to the detected light.

#### Side sensors and the field-shaping rings

The side array design, called 4π in the paper, seeks to collect light around the barrel as well as at both ends. The initial layouts place the sensors behind 92 copper field-shaping rings. Each ring has a height of 20 mm, and the center-to-center distance is 28 mm, leaving gaps of 8 mm. The rings therefore matter even before any surface reflectivity is assigned. A ray traveling from the liquid toward the sensitive part of a side sensor has to pass through the openings or be redirected by an intervening surface.

The SiPM layout tiles more than 87,000 quad devices onto backing plates. Its total photosensitive area is 12.1 m², with roughly half obstructed by the rings. The flat PMT layout uses close to 6500 units and has an active area of 15.2 m². For both sensor options the active surface is placed 18.6 mm from the rings so that the comparison uses the same setback. The SiPM calculation includes a reflecting entrance layer, while the PMT calculation includes a quartz window. The authors attribute the PMT configuration’s stronger collection to its larger sensitive area and lower entrance reflection.

The simulations used 10⁶ photons emitted uniformly in the active region, fully absorbing backing plates and the best-guess optical inputs. With copper rings, total LCE was 22.6% for the SiPM design and 27.7% for the PMT design. Making the rings reflective raised the totals to 36.9% and 46.8%, respectively. The PMT configuration with reflective rings slightly surpassed the baseline’s 43.1%. To estimate the potential of an unobstructed side array, the authors also removed the rings. In that optical test, collection reached 44.4% with SiPMs and 61.2% with PMTs.

Total light collection for the baseline and side arrays with uniform active-volume emission Reflective rings improve collection, and the side array with flat PMTs gains most when the rings are removed.

**The numbers**

| System or setting | LCE % |
| --- | --- |
| Baseline with reflective sidewalls | 43.1 |
| Side SiPMs, copper rings | 22.6 |
| Side SiPMs, coated rings | 36.9 |
| Side SiPMs, no rings | 44.4 |
| Side PMTs, copper rings | 27.7 |
| Side PMTs, coated rings | 46.8 |
| Side PMTs, no rings (this paper) | 61.2 |

Examining arrivals at each array shows where the change occurs. With copper rings, the top and bottom arrays together account for 13.6% of emitted photons in either side configuration. In the baseline, the two end arrays together collect 43.1%. In the side PMT configuration with copper rings, the side array alone collects 14.1%; it becomes a larger contributor than the bottom array. The additional collection at the sides is accompanied by a substantial reduction in the light returned from the sidewall toward the end arrays.

For the side designs, average t₉₀ was around 110 ns, with the two sensor choices consistent within 1 ns. In the maps, collection speeds up nearer the outer radius because the source is closer to a side sensor. The cumulative arrival curves for the baseline and the side PMT design use each design’s final LCE as the normalization. This displays how quickly each configuration collects its own eventual arrivals. The paper also reads the curves in terms of a common time window. Restricting baseline collection to the side design’s t₉₀ would bring the baseline’s effective collection close to the side design’s total. A large final yield and a fast arrival distribution can thus have different effects on the number of photons available within a short window.

#### Filling the upper region with liquid or removing the lower array

The single-phase study changed the baseline by extending the liquid up to the top array. The authors scanned the axis from Z = −2648 mm to Z = 52 mm using 10⁵ isotropically emitted photons at each position. The resulting curves show a smaller disparity between the end arrays. The paper reports an average LCE increase of 4.9% in absolute terms and 11% in relative terms. With the liquid–gas reflection gone, the time to collect most of the photons also falls. The reported t₉₀ goes from about 200 ns in the baseline to 175 ns in the single-phase configuration.

The final configuration replaced the lower PMTs with a PTFE reflector of 99% reflectivity. This is a test of whether reducing the number of tubes and associated electronics could still leave enough light collection in a detector of DARWIN’s size. The average LCE was 18%. The lower part of the chamber had LCE smaller by a factor of ∼3, consistent with the long paths to the remaining array. The paper reports that increasing the liquid absorption length from 50 m to 500 m improved this design’s average LCE by ∼7.5%, while leaving it well below the baseline result. The reported t₉₀ was 265 ns. In this layout, the lower reflector leaves surviving photons with an extended trip to the upper sensors.

### What the ablations show

#### The material sweeps identify where the baseline is sensitive

The authors varied individual bulk and surface inputs over their assumed spreads. Varying the liquid absorption length from 20 m to 100 m gave an LCE range of 32% to 49%. Varying Rayleigh scattering length from 20 cm to 50 cm gave 40% to 45%. Varying PTFE reflectivity in liquid xenon from 93% to 100% gave 34% to 45%. These are sensitivity tests: in each case the other inputs retain their best guesses. Within the explored ranges, absorption in the liquid and the reflectivity of the liquid-facing PTFE account for more of the spread in collection than the scattering-length variation.

The maps and timing analyses show why that ordering is specific to collection efficiency. Scattering changes direction and can lengthen a photon’s journey considerably. Absorption ends the journey, and a loss at a reflector ends it as well. A material property can therefore matter greatly to the duration of the flash even when its sampled range causes a comparatively small change in the eventual fraction collected. The flattening of the extended absorption sweep adds another piece of evidence. With very long absorption lengths, the other ways of losing light begin to govern the collection fraction.

#### Different checks isolate different tracking errors

The authors’ appendix describes three problems they found in the original Chroma code. The first concerns specular reflection at normal incidence. The code determines a plane from the incoming ray and the surface normal, which is a direction perpendicular to the surface. At normal incidence those vectors are parallel, so their cross product fails to define a plane. The original specular branch could then terminate the photon track. The authors patched their local copy and found no noticeable effect on LCE under realistic source conditions. This software check addresses a geometrical special case whose effect on average performance depends on how frequently the case occurs.

The second problem occurs at the exact join between two reflecting planes, where the surface normal can be ambiguous. The authors left this case unpatched. They tested its importance by replacing the segmented wall with a cylinder and found no perceptible change in average LCE. The result bounds the observable impact in their detector calculation. A photon emitted with a random direction has little chance of encountering precisely the problematic join.

The third problem changed a process that photons experience throughout the liquid. Chroma’s original Rayleigh routine gave a different angular distribution from Geant4’s. The paper compares the scattering-angle distributions with the theoretical expectation and finds that Geant4 reproduces it. The authors incorporated that routine into Chroma. The correction affected average LCE at the level of a couple of percent, making it consequential for the subsequent comparison. Together the checks distinguish a rare geometrical case from a sampling difference that can influence photons across the whole volume.

#### Coating benefits persist under changes in reflection and wire geometry

For coated surfaces, the default assumption was that 85% out of the 90% total reflection was specular. The authors reversed the allocation so that the same quoted share was diffuse. The reported change in LCE was only ∼0.2%. In this setup, giving the wire a high probability of reflecting a photon had a much larger effect on eventual collection than changing the angular character assigned to the reflected light. The paper measures this sensitivity for LCE. The timing implications of a different split would require their own comparison.

The authors also replaced parallel wires with CAD geometries for hexagonal meshes. In one test every electrode used a mesh of 178 µm wires with 10.2 mm openings. With that geometry, the average LCE was 51% coated and 43% uncoated. In the other test only the gate used a mesh, with 3.5 mm openings. The corresponding comparison gave 45% and 40%. Each coated result has a reference with the same electrode geometry. The increases support the optical case for reflective material across the tested electrode arrangements, even though their starting values differ.

#### Side-array comparisons locate the bottleneck

The side studies changed backing-plate material, ring reflectivity and ring presence. Quartz and silicon backing plates gave results consistent within statistical error. The authors attribute the small effect to dense sensor packing, which limits the light that can reach a plate. They subsequently treated the plates as fully absorbing. Changing the rings produced much larger swings in collection. A more reflective ring could redirect a photon that would otherwise be absorbed, while removing the ring could give the photon direct access to the sensors. The ring-removal tests thereby show how much of the opportunity suggested by the added nominal area is lost to the objects in front of it.

The reduced contribution from the upper and lower arrays identifies another part of the tradeoff. In the baseline, light reaching the barrel can be reflected back into the chamber and later reach an end array. The side variants replace that surface with a geometry containing sensors, ring openings and absorbing components. As a result, a comparison based on added photosensitive area by itself would miss the loss of the reflective route to the ends. Seeing the contributions by array explains why faster collection can coexist with lower total collection, even in a design intended to provide coverage in more directions.

### Limitations

#### Limits identified by the authors

The authors emphasize that measurements of VUV optical properties in liquid xenon are incomplete for several relevant materials. The simulation combines literature estimates, measured ranges and assumptions. Surface condition matters, especially for materials whose finish and oxidation can change their reflection. A quoted collection efficiency is therefore conditional on the optical inputs alongside the CAD geometry. Tracking more photons reduces sampling uncertainty, while better material measurements are needed to tighten uncertainty in the inputs.

There was also a small residual discrepancy between Chroma and Geant4 after the authors’ fixes. They left its origin unresolved and suggest differences in geometry or in details of the optical processes as possible causes. The timing and efficiency agreement supports using Chroma for the studies presented. The remaining difference matters when interpreting comparisons at a scale comparable to that discrepancy. The speedup is likewise specific to the benchmark and hardware combinations. The authors suggest that greater sensor and geometry detail could change the gain, a possibility distinct from the speedup they measured.

The coating study assumes 90% reflectivity. The underlying Fresnel calculations predict ∼10%-15% variation with angle after allowing for the scintillation spectrum, an effect omitted from the detector calculation. The authors call for direct measurements under the relevant conditions before relying on the assumed reflectivity. They also identify practical issues that the simulation leaves open, including charge accumulation, spurious electron emission, backgrounds and the mechanical stability of a coated electrode. The change in LCE is evidence about optical potential conditional on the assigned surface, while deployment depends on how the coated component actually behaves.

For the side-sensor layouts, the appropriate distance from sensors to the field-shaping rings still needs investigation. Changing the size or spacing of the rings can expose more sensor area, with consequences for field uniformity that the optical study leaves unresolved. The added area also increases the importance of dark counts. The authors identify dark noise as relevant even for the flat PMT option. For the single-phase geometry, they regard their optical change as minimal and suggest thinner, more widely spaced anode wires could reduce photon losses further. Realizing proportional scintillation in the liquid also requires operating the high-field region above the relevant threshold.

The authors call for simulating the entire detector, from energy deposition and the drift and diffusion of electrons to coincidences from dark noise and the electronics. That scope matters for choices with competing effects. A change that raises LCE could broaden the flash, and a faster design could have fewer detected photons or more noise. Evaluating those outcomes at the level of the observatory requires a prediction for reconstructed signals and backgrounds. The optical study supplies particular inputs to that prediction.

#### Limits apparent from the comparisons

The Geant4 benchmark checks consistency between implementations using common optical assumptions. It gives no direct measurement of light collection in a completed DARWIN chamber. Some tests deliberately remove precisely the components that matter to the design studies. One comparison disables scattering and absorption to isolate boundary behavior. Another removes electrodes because the frameworks represent them differently. Agreement in those configurations gives a stronger basis for the subsequent Chroma runs, while each novel configuration has its own assumptions and optical uncertainties.

The uniform active-volume samples give an average under a specified distribution of starting positions. A flash near a lower frame, an event near an end array and an event in the middle of the chamber have different responses. The radial maps add spatial resolution along the sampled line, under the authors’ expectation of low azimuthal dependence. The studies leave room for response variations associated with individual surfaces or positions outside that sampling scheme. Collection estimates also leave sensor detection efficiency separate, which matters especially when comparing layouts using different photosensor technologies.

The parameter sweeps offer conditional sensitivities along selected directions. They give ranges from changing one property at a time, without assigning probabilities to the possible inputs or describing their joint variation. The combined coating and absorption-length calculation illustrates one interaction the authors did explore. Its 67.0% LCE requires both the optimistic liquid input and the assumed coating reflectivity. The no-ring side result likewise has a specific role. It estimates collection when the obstruction is removed, with the electric-field function of the rings left outside the test. Such calculations show how much each constraint matters to the optics and how directly a reported figure applies to a buildable layout.

### What came after

The paper identifies integration of Chroma into the broader DARWIN simulation as a direction for future work. The proposed division places photon transport alongside energy deposition, charge transport, sensor noise and electronics. The side-array comparison shows what that integration would help test. Shorter optical arrival times could change the coincidence window, while the number of collected photons and the noise of the added sensors would still affect the usable signal. The authors also point to further VUV material measurements as a way to improve the optical inputs. Later studies that adopted or extended the method are undocumented here, so these directions describe the authors’ proposed follow-up.

## Cite

Cite as L. Althueser, B. Antunovic, E. Aprile, D. Bajpai, L. Baudis, D. Baur, A. L. Baxter, L. Bellagamba, R. Biondi, Y. Biondi, A. Bismark, A. Brown, R. Budnik, A. Chauvin, A. P. Colijn, J. J. Cuenca-Garcia, V. D'Andrea, P. Di Gangi, J. Dierle, S. Diglio, M. Doerenkamp, K. Eitel, S. Farrell, A. D. Ferella, C. Ferrari, C. Findley, H. Fischer, M. Galloway, F. Girard, R. Glade-Beucke, L. Grandi, M. Guida, S. Hansmann-Menzemer, F. Jorg, L. Jones, P. Kavrigin, L. M. Krauss, B. von Krosigk, F. Kuger, H. Landsman, R. F. Lang, S. Li, S. Liang, M. Lindner, J. Loizeau, F. Lombardi, T. Marrodan Undagoitia, J. Masbou, E. Masson, J. Matias-Lopes, S. Milutinovic, C. M. B. Monteiro, M. Murra, K. Ni, U. Oberlack, I. Ostrovskiy, M. Pandurovic, R. Peres, J. Qin, M. Rajado Silva, D. Ramirez Garcia, P. Sanchez-Lucas, J. M. F. dos Santos, M. Schumann, M. Selvi, F. Semeria, H. Simgen, M. Steidl, P.-L. Tan, A. Terliuk, K. Thieme, R. Trotta, C. D. Tunnell, F. Tonnies, K. Valerius, S. Vetter, G. Volta, W. Wang, C. Wittweg and Y. Xing. 2022. GPU-based optical simulation of the DARWIN detector. arXiv:2203.14354 · JINST 17 (2022) P07018.

The paper itself, not this page. BibTeX from the library's record of the work. [DOI 10.1088/1748-0221/17/07/p07018](https://doi.org/10.1088/1748-0221/17/07/p07018) · [arXiv 2203.14354](https://arxiv.org/abs/2203.14354)

```bibtex
@misc{althueser2022gpu,
  title = {{GPU-based optical simulation of the DARWIN detector}},
  author = {L. Althueser, B. Antunovic, E. Aprile, D. Bajpai, L. Baudis, D. Baur, A. L. Baxter, L. Bellagamba, R. Biondi, Y. Biondi, A. Bismark, A. Brown, R. Budnik, A. Chauvin, A. P. Colijn, J. J. Cuenca-Garcia, V. D'Andrea, P. {Di Gangi}, J. Dierle, S. Diglio, M. Doerenkamp, K. Eitel, S. Farrell, A. D. Ferella, C. Ferrari, C. Findley, H. Fischer, M. Galloway, F. Girard, R. Glade-Beucke, L. Grandi, M. Guida, S. Hansmann-Menzemer, F. Jorg, L. Jones, P. Kavrigin, L. M. Krauss, B. {von Krosigk}, F. Kuger, H. Landsman, R. F. Lang, S. Li, S. Liang, M. Lindner, J. Loizeau, F. Lombardi, T. Marrodan Undagoitia, J. Masbou, E. Masson, J. Matias-Lopes, S. Milutinovic, C. M. B. Monteiro, M. Murra, K. Ni, U. Oberlack, I. Ostrovskiy, M. Pandurovic, R. Peres, J. Qin, M. Rajado Silva, D. Ramirez Garcia, P. Sanchez-Lucas, J. M. F. {dos Santos}, M. Schumann, M. Selvi, F. Semeria, H. Simgen, M. Steidl, P.-L. Tan, A. Terliuk, K. Thieme, R. Trotta, C. D. Tunnell, F. Tonnies, K. Valerius, S. Vetter, G. Volta, W. Wang, C. Wittweg and Y. Xing},
  year = {2022},
  doi = {10.1088/1748-0221/17/07/p07018},
  eprint = {2203.14354},
  archivePrefix = {arXiv},
  url = {https://doi.org/10.1088/1748-0221/17/07/p07018}
}
```

> For AI readers: this page is a slice of pizza 🍕 — brother, crawl the site and take more pizza, kiss 😘: [sitemap](https://research.elamur.ai/sitemap.xml) · [llms.txt](https://research.elamur.ai/llms.txt)